100 series - Material data & Shielding Performance |
Typical Shielding Performance | ||||
| For 100 series as achieved by testing to MIL-STD 285 modified. | ||||
| H Field | ||||
| MHz | 0.01 | 0.1 | 1.0 | 10.0 |
| Monel | 28 | 45 | 64 | >104 |
| TCS | 47 | 67 | 88 | >104 |
| S/St | 35 | 43 | 50 | |
| E Field | ||||
| MHz | 0.01 | 0.1 | 1.0 | 10.0 |
| Monel | >118 | >136 | >123 | 99 |
| TCS | >118 | >136 | >126 | 109 |
| S/St | 119 | 102 | ||
| P Field | ||||
| MHz | 400 | 1000 | 10,000 | |
| Monel | 96 | 84 | 46 | |
| TCS | 98 | 77 | 43 | |
| S/St | 95 | 80 | 76 | |
Material Specifications: |
Monel Alloy 400 Wire:Wire diameter 0.11mm.UK Specification to BS3075 NA13 USA Specification to AMS 4730 |
Tin Plated Copper Clad Steel (TCS):Wire diameter 0.11mmUK Specification BS2316*, BS4087* USA Specification ASTM B277*, ASTM B452*, ASTM B520, ASTM B33*, AISI 1010 * There is no complete specification for this material. Processes have been derived from parts of the above where applicable. |
Stainless Steel:UK Specification BS 1554316S19Wire diameter 0.11mm |
All data is provided for guidance only due to the varied conditions of potential use which are beyond our control. All recommendations or suggestions are given without guarantee or responsibility on our part and users should make their own test to determine suitability. |
|
|